Buy Allen Bradley, diverse MicroLogix Series PLC I/O Module 4 Inputs, ±21 mA – 10 → 10 V dc, 87 x 40 x 90 mm IF4. Browse our latest plc-i-o-modules. Question. Where can I find information on IF4 Analog Input Data format? Environment. IF4 MicroLogix Analog Input Card. Find great deals for Allen-Bradley IF4 (IF4) Analog Input Module. Shop with confidence on eBay!.

Author: Nejinn Mogor
Country: Liechtenstein
Language: English (Spanish)
Genre: Politics
Published (Last): 11 May 2007
Pages: 428
PDF File Size: 18.12 Mb
ePub File Size: 7.8 Mb
ISBN: 404-6-75859-215-5
Downloads: 57156
Price: Free* [*Free Regsitration Required]
Uploader: Mazilkree

The IF4 module has a single status LED that indicates power and helps identify the source of all problems. Its analog operating current range is 4 to 20 mA normal and to 21 mA at full scale. There is an optional memory module that provides programmatic and data backup with the capability for uploads and downloads. It converts the analog input up to the full-scale range.

The operation details must be configured 176-2if4 each channel after module installation. This results in larger control systems, greater application flexibility, and expandability at a lower cost and reduced parts inventory Technical specifications: The lowest-priced brand-new, unused, unopened, undamaged item in its original packaging where packaging is applicable. We have ratings, but no written reviews for this, yet. In Stock Ships Today.

Related Posts (10)  WEB ENGINEERING GERTI KAPPEL PDF

Show More Show Less. Be the first to write a review. It has dimensions of 90 x 87 x For wiring the input terminal blocks, a finger-safe cover is present.

When selecting 162-if4 signal delays, the options are: Skip to main content.

Scripting must be enabled to use this site.

People who bought this also bought. It requires minimal spacing and can be either DIN rail or panel-mounted. There is also an optional provision for scheduling and controlling tasks with the real-time clock. Belden shielded Enclosure Type Rating: D Micro Programmable Logic Controllers.

A field-upgradable flash operating system that helps to make sure you will always be up-to-date with the latest features, without having to replace hardware. Safety circuits should always be wired in series to the master relay. What are the typical update times for the IF4? This powerful memory store provides percent data retention.

It enhances the functionality of MicroLogix controllers. This results in larger control systems, greater application flexibility, and expandability at a lower cost and reduced parts inventory.

IF4 – In Stock | Allen Bradley PLC MicroLogix

The IF4 module should be installed in non-hazardous, dry, and clean environments with circuits not crossing overvoltage category II standards. This item doesn’t belong on this page. It has a Delta-Sigma converter and 4 differential bipolar inputs. The typical update times for the IF4 are,and milliseconds. The module communicates and receives information on 5 to 24 Volts DC power via the bus interface. The input type is 24V with a DC sink or source.

Related Posts (10)  PROCESOS DE MANUFACTURA VERSION SI AMSTEAD PDF

See details for additional description. See all 6 brand new listings.

The MicroLogix controller provides more computing power and flexibility than the MicroLogix controller to solve a variety of application needs. This analog input module has a relay contact output type. Packaging should be the same as what is found in a 1762if4 store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag.

The IF4 module can be connected to 3 types of transmitters i. Any Condition Any Condition. The controller can be easily updated to 1762-of4 latest firmware via a website download. To avoid damage to the module, always prevent electrostatic discharge and remove power. Its analog operating voltage range is around 10 Volts DC normal and