ASTM C() Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill Paperback – April 1. ASTM A/AMa Testing Mechanical Splices for Steel Reinforcing Bars .. ASTM C Concrete Sewer Manholes by the Negative Air Pressure. This standard is issued under the fixed designation C; the 1 This test method is under the jurisdiction of ASTM Committee C13 on.

Author: Mautilar Bashakar
Country: Paraguay
Language: English (Spanish)
Genre: Love
Published (Last): 16 March 2005
Pages: 387
PDF File Size: 12.27 Mb
ePub File Size: 13.76 Mb
ISBN: 872-5-70081-211-8
Downloads: 93130
Price: Free* [*Free Regsitration Required]
Uploader: Tamuro

If we were to round up to a foot depth of bury, we would need the mercury to hold for at least 40 seconds. If the manhole fails the initial test, it may be repaired by an approved method until a satisfactory test is obtained.

Already Subscribed to this document. Subscription pricing is determined by: Vacuum testing in the presence of ground water Vacuum testing after backfilling should be performed only after a successful nonbackfill test has been completed in accordance with ASTM C External Pressure at Critical Depth Hydrostatic pressure.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Please first log in with a verified email before subscribing to alerts.

ASTM-C, –

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Depth to water table 2.

Related Posts (10)  EREC REX THE SECRET OF ASHONA PDF

Proceed to Checkout Continue Shopping. Note 1—Vacuum test criteria presented in this test method are similar to those in general use. Need more than one copy? Therefore, when the manhole is being vacuum tested, we would create a vacuum measuring 10 inches Hg and we would measure the amount of time it takes for the vacuum to drop from 10 inches Hg down to 9 inches Hg.

Vacuum testing is a quick, safe and practical way to validate manhole system integrity.

Vacuum Testing Precast Concrete Manholes

D1244 have no amendments or corrections for this standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Print 1 2 3 4 5 page sstarting from page current page. Today, some 12, ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence.

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

Note 2The v1244 of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests. The user of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests. This standard is not included in any packages. A vacuum test should not be performed when the hydrostatic head exceeds 22 feet. Enter your account email address to request a password reset: The test and criteria have been widely and successfully used in testing manholes.

Related Posts (10)  SOUNDARYA LAHARI SLOKAS IN SANSKRIT PDF

You may delete a document from your Alert Profile at any time. A water column of When to vacuum test Many codes and specifications require that a vacuum test be performed after the manhole has been installed and backfilled. Kayla Hanson, one of our technical engineers, has provided the following response: Please first verify c12244 email before subscribing to alerts.

Nails, Spikes, and Staples. FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER. The table in the ASTM lists the depths of bury in c244 of two feet. Register for a trial account.

In short, it sounds like you are reading and interpreting the table correctly. If the document is revised or amended, you will be notified by email. Internal Pressure at Critical Depth Vacuum pressure.

For more information Click Here Vacuum testing is a quick, safe and practical way to validate manhole system integrity.

Vacuum Testing Precast Concrete Manholes

This test method is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed atm. I want to point out the second paragraph on Page 3. This test method is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed joints. There were no books found for the applied search filters.

Vacuum test criteria presented in this test method are similar to those in general use.